User Service Guide, Third Edition - HP Integrity cx2620 Server

Log Entry 14: 28 Feb 2003 16:41:46
Alert Level 2: Informational
Keyword: BOOT_START
CPU starting boot
Logged by: System Firmware 0
Data: Implementation dependent data field
0x5680006300E000F0 0000000000000000
Log Entry 15: 28 Feb 2003 16:41:47
Alert Level 2: Informational
Keyword: Type-02 127002 1208322
Soft Reset
Logged by: BMC; Sensor: System Event
0x203E5F914B020110 FFFF027000120300
Keyword Mode Example:
13 BMC 2 0x203E5F914A0200E0 FFFF010944080300 Type-02 080901 526593
28 Feb 2003 16:41:46
14 SFW 0 2 0x5680006300E000F0 0000000000000000 BOOT_START
28 Feb 2003 16:41:46
15 BMC 2 0x203E5F914B020110 FFFF027000120300 Type-02 127002 1208322
28 Feb 2003 16:41:47
Accessing the Logs With BMC CLI Commands
The fpl command displays the forward progress log. For example:
Type 1 2 3 4 5 6 7
02 0000000E - Pwr Spply 1 Ctrl Enabled 44-08:09:01 2003-02-28 16:41:46
E0 0000000F 2 CPU0 Boot start 00063 DT 06 0000000000000000
E0 00000010 2 CPU0 Boot start 00063 Time 2003-02-28 16:41:46
E0 00000011 0 CPU0 00020 DT 00 0000000000000000
E0 00000012 0 CPU0 0000E DT 06 0000000000010000
E0 00000013 1 CPU0 CPU monarch 0000C DT 06 0000000000000000
E0 00000014 1 CPU0 CPU present 00261 DT 06 0000000000000000
E0 00000015 0 CPU0 00008 DT 00 0000000000000000
E0 00000016 0 CPU0 0024B DT 00 0000000000000000
E0 00000017 0 CPU0 00006 DT 03 0000000000000000
E0 00000018 0 CPU0 00044 DT 06 02000000002C0400
02 00000019 - BMC LPC reset 00-12:70:02 2003-02-28 16:41:47
The sel command displays the system event log. For example:
Type 1 2 3 4 5 6
7
02 00E0 - Pwr Spply 1 Ctrl Enabled 44-08:09:01 2003-02-28 16:41:46
E0 00F0 2 CPU0 Boot start 00063 DT 06 0000000000000000
E0 0100 2 CPU0 Boot start 00063 Time 2003-02-28 16:41:46
02 0110 - BMC LPC reset 00-12:70:02 2003-02-28 16:41:47
Each column in the log contains a different data field:
1 Record ID
2 Severity for E0 messages
3 Generator ID or sensor reporting the event
4 Text description of events
5 Sensor number - Sensor Type: Event Type: Data1 fields for type 02 messages (triplet) event
ID for E0 messages
6 Data2 and Data3 for type 02 messages (if applicable) or data type for E0 messages
7 Timestamp or extended data specific to the event
Event Logs for Troubleshooting Diagnostics 141