User Service Guide, Third Edition - HP Integrity cx2620 Server
NOTE: Hot-swapping a fan can interrupt system operation. If you are hot-swapping a fan
assembly in response to an error message, and the system is operating normally, hot-swapping
the fan in less than 30 seconds eliminates the requirement for a system reboot. Hot-swapping
the fan in less than two minutes enables continued operation and prevents automatic shutdown.
Installing a Rear Panel Hot-Swappable Fan
You do not need to remove the server from the rack to replace a fan. To remove a hot-swappable
fan from the rear of the server chassis, follow these steps:
1. Orient the replacement fan assembly so that the curved handle is at the bottom. Gently push
the fan unit into position.
2. Tighten the two captive screws that secure the fan unit to the server chassis.
NOTE: Hot-swapping a fan can interrupt system operation. If you are hot-swapping a fan
assembly in response to an error message, and the system is operating normally, hot-swapping
the fan in less than 30 seconds eliminates the requirement for a system reboot. Hot-swapping
the fan in less than two minutes enables continued operation and prevents automatic shutdown.
Removing and Replacing Hot-Swappable Power Supplies
Hot-swappable power supplies 1 and 2 are located at the rear of the chassis. These power supplies
are identical and interchangeable.