User Service Guide, Third Edition - HP Integrity cx2620 Server
2. When the power supply is fully inserted into the server chassis, tighten the two mounting
screws to secure the power supply in place.
3. Press up on the two lower tabs on the terminal barrier strip cover to snap off the cover.
WARNING! Always check that the power cable is not connected to a power source before
attempting to connect the power cable to the power supply terminals. Failure to heed this
warning can result in injury.
4. Connect the power cable leads to the power supply terminals (Figure 6-7).
Figure 6-7 Power Supply Terminals
Fault
DC Out DC In
Fault
DC Out DC In
rearview
dc Power
Supply Wire
dc Power
Supply Wire
dc Power
Supply Wire
dc Power
Supply Wire
5. Reinstall the terminal barrier strip cover. Hang the cover on the upper tabs and snap the
cover into place.
6. Route the power cable through the power supply cable clamp and tighten the two knurled
knobs to secure the cable in place.
7. Connect the power cable to the DC power source.
Removing and Replacing Hot-Pluggable Disk Drives
Hot-pluggable disk drives are located at the front of the server. The following sections explain
how to remove and reinstall a disk drive.
Removing and Replacing Hot-Pluggable Disk Drives 165










