User Service Guide, Third Edition - HP Integrity cx2620 Server
Figure 6-11 Installing the PCI-X Card Cage
chaspciccup
PCI Card Cage
Release
Lever
4. Press the release lever down to lock the card cage in place in the chassis.
5. Reinstall the chassis cover. See “Removing and Replacing the Top Cover” (page 158).
6. Reinstall the server in the rack and power on the server. See “Inserting the Server Into a
Rack” (page 156).
7. Run the info io command at the EFI Shell to verify that you have correctly installed the
PCI-X cards.
Removing and Replacing Hot-Pluggable PCI-X Cards
The server has four 64-bit, 133 MHz PCI-X accessory card sockets located in a removable card
cage. You must remove the PCI-X card cage before removing or installing PCI-X cards. The
following sections explain how to remove and install PCI-X cards.
PCI-X Configurations
PCI-X slots are numbered 1 through 4 from the top down in the server; 4 is the outermost slot.
Configuration requirements for slots 1 through 4 are as follows:
• Slot 1: The maximum speed for a card in slot 1 is 133 MHz. If you use different modes, such
as PCI-X instead of PCI-X, or different card speeds, the slot automatically downgrades to
the lesser mode or speed.
• Slots 2 - 4: The maximum speed for cards in slots 2 - 4 is 133/2 MHz.
170 Removing and Replacing Components