User Service Guide, Third Edition - HP Integrity cx2620 Server
Figure 6-16 Airflow Guides
chascvroff
Memory
Airflow
Guide
PCI
Airflow
Guide
Processor
Airflow
Guide
NOTE: Air flows through the server chassis from front to back.
Removing the Memory Airflow Guide
To remove the memory airflow guide, follow these steps:
1. Power off the server.
2. Remove the top cover. See “Removing and Replacing the Top Cover” (page 158).
3. Grasp the memory airflow guide and lift it from the server chassis.
Installing the Memory Airflow Guide
To install the memory airflow guide, follow these steps:
1. Reposition cables away from the area where you install the airflow guide.
2. Align the tab on the airflow guide with the corresponding slot on the server chassis.
3. Insert the tab into the slot and set the memory airflow guide in place above the DIMMs and
DIMM connectors.
Removing the Processor Airflow Guide
To remove the processor airflow guide, follow these steps:
1. Power off the server.
2. Remove the top cover. See “Removing and Replacing the Top Cover” (page 158).
3. Grasp the processor airflow guide and lift it from the server chassis.
Installing the Processor Airflow Guide
To install the processor airflow guide, follow these steps:
1. Align the tabs on the airflow guide with the corresponding slot on the server chassis.
176 Removing and Replacing Components