User Service Guide, Third Edition - HP Integrity cx2620 Server

Removing the iLO MP Card
To remove the iLO MP card, follow these steps:
1. If rack-mounted, extend the server out from the rack until it stops. See “Installing Components
When the Server Is in a Rack” (page 154).
2. Power off the server. Disconnect all external cables.
3. Remove the server from the rack and place it on an ESD-protected work surface. See
“Removing the Server From a Rack” (page 155).
4. Remove the top cover. See “Removing and Replacing the Top Cover” (page 158).
5. Remove the processor airflow guide. See “Removing the Processor Airflow Guide” (page 176).
6. From the rear of the chassis, remove the two screws (hex 2-56 w/slot stainless steel) securing
the 25-pin serial port connector on the back of the iLO MP card to the server chassis.
7. Remove the two noncaptive screws (M3 x 6mm long pan T15/slot square cone stainless steel)
on top surface of the iLO MP card, securing the assembly to its mounting standoffs.
Figure 6-28 iLO MP Card Mounting Screws
chasmpbrdxtnd
8. Disconnect the low-profile ribbon connector from the system board.
9. Pull the disconnected iLO MP card toward the front of the server chassis and remove it from
the server.
Removing and Replacing the iLO MP Card 191