Figure 1-12 System Board LEDs
Table 1-11 lists the system board LEDs.
Table 1-11 System Board LEDs
DescriptionLED
The standby LED displays the power status of the server. It is lit when power is applied (DC In
LED on either power supply is lit). If power is applied and this indicator is off, you may have to
replace the system board.
Standby
The baseboard management controller (BMC) heartbeat LED flashes whenever the BMC is active.
If this indicator is not blinking when the server is powered on (STBY LED is lit), you may have to
replace the system board.
BMC
The firmware LED lights when the boot process begins. If the server will not boot, and this LED
is off, you may have to replace the system board.
Firmware