User Service Guide, Third Edition - HP Integrity cx2620 Server
Figure 3-12 Installing the PCI-X Card Cage
3. Press the release lever down to lock the card cage into place in the chassis.
4. Install the chassis top cover. See “Installing the Top Cover” (page 64).
5. Reconnect rear panel cables, and turn on the system.
6. To verify that you have correctly installed the PCI-X card, run the info io command at
the EFI Shell.
Installing Single-Core Processors
The single-core processors are located on the system board and are accessible after removing the
top cover and air guides. Processor 0 (CPU 0) is located closer to the chassis side panel and
processor 1 (CPU 1) is located closer to the DIMM sockets (Figure 3-13).
The server may be delivered with one or two single-core processors installed. You can install the
second processor, or replace the processors with newer, compatible processors. The following
sections provide detailed procedures for processor installation.