Asynchronous Terminals and Printer Processes Programming Manual

APPENDIX A
CONSOLE MESSAGES
This appendix summarizes the console error messages that are
generated by ATP6100, TERMPROCESS, and SERIALPRINTPROCESS. The |
messages preceded by an asterisk (*) are not used for the 3681 |
controller. |
CONSOLE ERROR MESSAGES SENT BY ATP6100
ATP6100 generates the following console error messages:
67 LDEV
ldev
SUBDEV
ddd
ERROR
errnum
Sent when a subdevice is placed in the stopped state.
ERROR = 100 when subdevice cannot be started because of
bad configuration.
74 PROCESS INTERNAL ERROR
parameter-3
parameter-4
parameter-5
The ATP6100 process detected an internal problem.
The reason for the problem is returned in
parameter-3
,
which can be one of the following:
%1001 Tried to receive a frame while level 3 was
still using receive buffer.
%1002 Invalid CLIP function received.
parameter-4
contains the function modifier field.
%1003 1. Activate path timed out, or
2. Reset sequence numbers request timed out, or
November 1987 A-1