Asynchronous Terminals and Printer Processes Programming Manual

CONSOLE MESSAGES
Console Error Messages Sent by ATP6100
| *164 LDEV
ldev
CU
ccu
CSS LINE ERROR, CIU
path
parameter-3
parameter-4
parameter-5
parameter-3
= function/modifier field
parameter-4
= first data word
parameter-4
= second data word
Sent for one of the following reasons:
1. Bad subdevice number in message from CLIP.
2. Nonzero CLIP status byte in a response to a CLIP
START, STOP, or SET CONFIGURATION request.
165 LDEV
ldev
CU
ccu
CSS SUBDEVICE ERROR, CIU
path
parameter-3
parameter-4
parameter-5
parameter-3
= subdevice number
parameter-4
= function/Modifier field
parameter-5
= CLIP status field
The returned modifier byte has its high-order bit turned
on when an error is returned by the CLIP. The error is
returned by the CLIP in
parameter-5
, which can be one of
the following:
1 EOF character detected
2 Break detected
3 Operation timed out
4 Modem error detected
5 Modem disconnected
6 Parity error detected
7 SIO overrun occurred
8 Character framing error
9 Unrecoverable terminal error
10 No buffer available for read
11 Line not configured
12 Line not started
13 Trace already active
14 No trace is active
15 Request is not valid
16 Invalid subdevice specified
17 Internal state machine error
18 Terminal was powered on
19 Invalid ETX parameter
20 Invalid baud rate parameter
21 Invalid character size
22 Invalid parity specified
23 Invalid number of stop bits
24 Invalid special line termination mode
25 Invalid backspace type
26 Request was canceled
A-4 November 1987