Asynchronous Terminals and Printer Processes Programming Manual

CONSOLE MESSAGES
Console Error Messages Sent by ATP6100
27 No active request to cancel
28 Invalid write count specified
29 Invalid read count specified
30 Invalid L4 specified
31 Line already started
32 Active request is pending
33 Modem failure due to CTS
34 Modem failure due to SDCD
35 * Baud rate selected conflicts with other channel's
baud rate
36 * Baud rate not supported by this interface
37 ** No response received from printer
38 ** Printer is not ready
39 ** Printer error
40 ** Paper out
41 ** VFU buffer error
* For CLIP4 only
** For printer only
Only 5520 and 5530 have
parameter-5
= 39. When this is
true,
parameter-4
primary/auxiliary status instead of
function/modifier.
parameter-4
.
0:7
= primary printer status
parameter-4
.
8:15
= auxiliary printer status
CONSOLE ERROR MESSAGES SENT BY TERMPROCESS
TERMPROCESS generates the following console error messages:
04 LDEV
ldev
CU
ccu
ERROR
dev-status
parameter-1
parameter-2
parameter-3
{BELL}
This message indicates that a controller error occurred.
The parameters are as follows:
ldev
logical device number of the affected
terminal
ccu
controller number
dev-status
interrupt status from the controller
parameter-1
= %000213
parameter-2
= %000000
parameter-3
= %000000
November 1987 A-5