Asynchronous Terminals and Printer Processes Programming Manual

CONSOLE MESSAGES
Console Error Messages Sent by SERIALPRINTPROCESS
The parameter values are interpreted as follows:
For controller errors (
parameter-1
=%000213),
dev-status
contains interrupt status from the controller and both
parameter-2
and
parameter-3
are %000000.
For the model 5520 printer:
dev-status
is the primary status returned from the
printer.
parameter-1
is the auxiliary status word if bits
9 through 11 of
dev-status
are equal to 7; otherwise,
parameter-1
is %000000.
parameter-2
is the GUARDIAN file-system error number.
parameter-3
is %000000.
SYSTEM The system waits until the problem is
ACTION: corrected.
RECOVERY: Check the printer for a possible problem.
For the model 5530 printer:
dev-status
is the primary status returned from the
printer.
parameter-1
is the auxiliary status if the primary
status indicates that one is available.
parameter-2
is the GUARDIAN file-system error number.
parameter-3
is %000000.
Operator console message #4 is issued for the following
file-system errors:
Decimal Octal Description
120 %000170 Data Parity Error
121 %000171 Data Overrun Error
139 %000213 Controller Error
140 %000214 Modem Error |
190 %000276 Device Error
191 %000277 Device Power-On
SYSTEM The system waits until the problem is
ACTION: corrected.
RECOVERY: Check the printer for a possible problem.
November 1987 A-7