Asynchronous Terminals and Printer Processes Programming Manual

CONSOLE MESSAGES
Console Error Messages Sent by SERIALPRINTPROCESS
05 LDEV
ldev
CU
ccu
RETRY
dev status
parameter-1
parameter-2
parameter-3
This message indicates that an error occurred with the
specified printer and the operation is being retried.
The parameters are as described above for the operator
console message.
06 LDEV
ldev
CU
ccu
UP
CAUSE: The operator successfully returned the
printer to the system through a Peripheral
Utility Program UP or REVIVE command.
SYSTEM The operation is completed; the printer is
ACTION: up.
RECOVERY: Informative message only; no corrective
action needed.
07 LDEV
ldev
CU
ccu
DOWN {BELL}
CAUSE: The operator removed the printer from the
system with a Peripheral Utility Program
DOWN command.
SYSTEM The operation is completed; the printer is
ACTION: down.
RECOVERY: If a DOWN command did not cause this message,
call your Tandem representative.
74 LDEV
ldev
CU
ccu
PROCESS INTERNAL ERROR
parameter-1
parameter-2
parameter-3
{BELL}
CAUSE: A communication process detected an error.
The
parameter
values contain specific error
information, which is process-dependent.
RECOVERY: If the I/O process can recover from the
internal error, it will. If not, report this
and other related messages to your Tandem
representative.
A-8 November 1987