Asynchronous Terminals and Printer Processes Programming Manual

CONTROL, SETMODE, AND SETPARAM FOR TERMINALS
SETMODE Operations
67 = AUTODCONNECT for full-duplex modems. Monitor carrier
detect or data set ready.
parameter-1
= 0 disable AUTODCONNECT (default)
1 enable AUTODCONNECT
parameter-2
is not used.
110 = Set shift in/shift out (SISO) code extension.
parameter-1
= 0 disable SISO (default)
1 enable SISO
NOTE
SETMODE 110 is supported in ITI protocol when used for
6530 terminals.
parameter-2
is not used.
113 = set screen size.
parameter-1
= screen width (40, 66, 80, or 132)
parameter-2
= screen length (25 or 28)
last-parameters
is an integer reference that contains two
elements.
last-parameters
[0] = old
parameter-1
[1] = old
parameter-2
NOTE
| SETMODE 113 is supported by both ATP6100 and TERMPROCESS.
114 = download 6530 emulation code.
parameter
= 0 stop downloading (default)
1 start downloading
B-6 November 1987