Asynchronous Terminals and Printer Processes Programming Manual

3681 MULTIFUNCTION CONTROLLER
Console Messages for the 3681
| CONSOLE MESSAGES FOR THE 3681
|
|
| Console messages posted by CSM cannot be logged for the 3681
| implementation because CSM is not defined for the 3681 implemen-
| tation of ATP6100. In addition, console messages related to
| the download operation are not logged for 3681. However, the
| following console messages will continue to be logged for 3681:
|
| 04 device error
| 06 line or device UP message
| 07 line or device DOWN message
| 74 process internal error
| 165 CSS subdevice error
|
|
|
| CMI LIMITATIONS FOR THE 3681
|
|
| The 3681 implementation allows you to issue most CMI commands.
| However, there are some limitations associated with the ALTER,
| CONTROL, INFO, and STATUS commands. In addition, statistical
| items, as well as the SU object, are affected.
|
|
|
| ALTER Command Limitation
|
|
| The attributes associated with the LINE object are not alterable
| using the ALTER command. If you attempt to alter these
| attributes with the ALTER command, a FEINVALOP (02) message
| displays indicating the attribute has been rejected.
|
|
|
| CONTROL Command Limitation
|
|
| The 3681 does not support the CONTROL command because the
| controller is not downloaded from the NonStop System. If you
| attempt to issue the CONTROL command, a FEINVALOP (02) message
| displays. This message indicates the command has been rejected.
|
|
|
| INFO Command Limitation
|
|
| Line attributes do not apply to the 3681 implementation. The
| DEBUG, PROGRAM, and PROTOCOLID fields in the INFO display are
| blank.
F-4 November 1987