Asynchronous Terminals and Printer Processes Programming Manual

|
|
|
|
|
|
|
|
|
|
APPENDIX G |
|
DIP SWITCH SETTINGS FOR 5573 PRINTERS |
|
|
|
|
|
This appendix lists the possible dip-switch settings for 5573 |
printers, which are supported by ATP6100/CSSPRINT and |
SERIALPRINTPROCESS. Some of the switches have a corresponding |
SETMODE operation; however, the SETMODE operation does not |
override the dip-switch setting. The SETMODE operation must be |
consistent with the switch setting; otherwise, the printer will |
not function. |
|
|
NOTE |
|
Dip switch 8 does not provide particular functionality. |
However, the switch must be set to OPEN. |
|
|
|
BAUD RATE SELECTION |
|
|
Dip switches 1 through 3 select the baud rate at which the 5573 |
printer operates. The corresponding SETMODE operation is SETMODE |
22 (see 22 in Appendix C for the correct parameter setting). The |
possible dip-switch settings are as follows: |
|
baud rate switch 1 switch 2 switch 3 |
|
1200 open closed open |
2400 closed closed closed |
4800 open closed closed |
9600 closed open closed |
19200 open open closed |
|
The 5573 printer cannot support baud rates slower than 1200 baud. |
|
November 1987 G-1