Number Text Explanation Action
3429 Anomaly getting tape
configuration from %s:
%s. %s.
Error or warning when
analysing the output of
a NonStop utility
reporting NonStop
configuration.
Case “ Host lun %ld in
clim %s from climcmd
lunmgr --print was not
memorized from scf
info clim”:
A tape drive was
discovered by a CLIM,
but not defined as a
TAPE in SCF. This
might be:
- left as is,
- ‘fixed’ by defined a
TAPE in SCF,
- ‘fixed’ by reducing
the number of
supported virtual
drives in the
FCConfig.txt file of the
VTC (need to restart
the Emulator Windows)
Case “VLE tape %s
returned by STATUS
TAPE was not stored
from INFO CLIM”:
Discrepency was found
between two query
output. Retry once,
before contacting
Etinet support
3430 %ld VLE drives not
connected to the CLIMs
associated to the Key
manager %s.
This message is
embedded in msg 3227
reporting a failed load.
Fix the configuration of
the Key manager.
3431 %ld drives reserved for
explicit allocation only,
or dont match explicit
allocation
This message is
embedded in msg 3227
reporting a failed load.
None. When a drive
without reservation will
become unloaded, the
load will be successful.
3432 Special character ‘%s’ in
'%s' is forbidden for
%Store ID"
The syntax of the
entered value is not
supported.
Enter a value without
the special character.
3433 No Volume group in the
domain configuration
refers to a tape
catalogue in node %s
A virtualization is
submitted with
searching the tape
catalogs in a given
node, but the BackPak
configuration does not
refer to any tape
catalogue in this node.
Verify the tape
catalogue specified in
the configuration of all
possible Volume
groups