BackPak H4.00 Troubleshooting and Messages Manual
Messages
111 BackPak H4.00 Troubleshooting & Messages
Number Text Explanation Action
3501 CONNECT to BB-
DOMAIN SERVER failure,
error %1
The EMS Extractor failed
to connect to the
Domain Manager.
Refer to the TCP/IP
Programming HP
NonStop manual.
Socket errors.
3502 WRITE to BB_DOMAIN
SERVER failure, error
%1
The EMS Extractor failed
to connect to send data
to the Domain Manager.
Refer to the TCP/IP
Programming HP
NonStop manual.
Socket errors.
3503 READ from BB_DOMAIN
SERVER failure, error
%1
The EMS Extractor failed
to connect to read data
from the Domain
Manager.
Refer to the TCP/IP
Programming HP
NonStop manual.
Socket errors.
3505 Domain manager reply:
%s
A GET Pending Mounts
was rejected by the
Domain Manager to the
EMS Extractor.
Refer to the reply
message of the
Domain Manager.
3506 Max Retries (%1)
reached for load request
%1 on %2. No more
retry
The number of retries
reached the max-
failsafe-retries
configured for the EMS
Extractor.
Check the status of
virtual devices.
Check the BBEXTCFG
configuration file.
3507 MAX-PENDING-
MOUNTS(%1) reached
An internal limit was
reached.
Contact the Product
Support.
3508 BBEXT must be started
by a user in SUPER
group, current user: %1
The EMS Extractor must
run under a User ID in
the SUPER group.
Restart BBEXT with a
User ID in the SUPER
group.
3509 Running BBEXT requires
infile: run BBEXT/in
BBEXTCFG ,name/
BBEXT needs a
configuration file in its
standard input.
Check the TACL RUN
command, or the SCF
definition that registers
BBEXT as a permanent
process.
3510 Unable to get required
parameter from EMS-
event: %1 error,
ignoring this mount
BBECT is unable to
extract a tape-related
event from EMS.
None, if no other
symptoms occur.
3511 %s loaded in
VTController at %s for
mount request %ld, but
the request is still
pending. Load being
retried
A volume load was
successful, but the
mount Id is still in the
list of pending mounts.
A new attempt is
executed.
Check the outcome of