BackPak H4.00 Troubleshooting and Messages Manual
Messages
112 BackPak H4.00 Troubleshooting & Messages
Number Text Explanation Action
3512 Loading of %s initiated
in VTController at %s for
request %ld, but the
request is still pending
A volume load was
successfully initiated,
but the mount Id is still
in the list of pending
mounts.
A restore script was
initiated but did not
complete successfully
yet.
Check the log of the
restore script.
3513 BBEXT config error: %s There is an error in
BBEXTCFG file.
Refer to the BBEXT
section of the
Installation chapter.
3514 BBEXT cannot open EMS
filter file %s, errno=%d.
The EMS filter that
reduces the traffic
between the EMS
distributor and BBEXT
can not be opened.
Verify the EMS filter
file name in the file
BBEXTCFG, and file
security.
The distributed EMS
file is named
EMSFILT1.
3516 Pre-load for volume %ld
%s continuation of %s is
not initiated. %s was
already requested on
%s by the mount-id
%ld.
Informative message None
3517 EMS Extractor started
for domain %s
(BBEXTversion)
Informative message None
3518 Invalid label type %d
associated to mount
request %ld volume %s
in MEDIASRV.
Unexpected code for the
label type in a mount
request description
provided by MEDIASRV.
Report the warning to
the product support.
Verify the correct
volume loading for the
tape application.
Eventually load the
volume through the
web application
3519 Mount request %ld for
%s not sent to Domain
manager because of
previous errors
See previous EMS
messages
Verify the correct
volume loading for the
tape application.
Eventually load the
volume through the
web application