BackPak H4.00 Troubleshooting and Messages Manual
Messages
117 BackPak H4.00 Troubleshooting & Messages
Number Text Explanation Action
4512 %s: File system error
(%d) occurs while
communicating with
process %s
Severe error occurred in
communication with the
Open SCSI device IOP
(media changer).
Search for EMS
messages issued by
the Open SCSI IOP.
Restart the Open SCSI
device in SCF.
4513 %s: File system error
(%d) with BUFFER-
status (%d) occurs while
communicating with
process %s
Severe error occurred in
communication with the
Open SCSI device IOP
(library media changer).
Search for EMS
messages issued by
the Open SCSI IOP.
Restart the Open SCSI
device in SCF.
4514 %s: Detecting error
while parsing READ
ELEMENT STATUS"
Error in the parsing of a
reply of the library
media changer.
Search for diagnostics
on the library console.
Search for EMS
messages issued by
the Open SCSI IOP.
Restart the Open SCSI
device in SCF.
4515 %s is DOWN The Open SCSI device
controling a library
media changer is down.
Restart the Open SCSI
device in SCF.
4516 Volume movement by
from %s to %s %s is
prohibited by the MEDIA
CHANGER model
A media move is
rejected by the library
media changer.
Contact the Product
Support.
4517 %s does not exist on
this system
The Open SCSI device
controling a library
media changer does not
exist.
In SCF, define and
start the OPEN SCSI
device named in the
BackPak library
configuration.
4518 %s: Guardian error %d
on %s"
Severe error occurred in
communication with the
Open SCSI device IOP
(media changer).
Search for EMS
messages issued by
the Open SCSI IOP.
Restart the Open SCSI
device in SCF.