Number Text Explanation Action
5021 Label type (%1) not
supported for %2
Internal error. Contact the Product
Support.
5022 Tape %1 already in use
by another device
The volume is already
used by another device.
Try a manual load.
If the problem re-
occurs, reset the VTC
whenever possible.
5023 Error getting the file size
of %1 (%2)
Error getting attributes
of a disk file in a
WINFILE DataStore.
Contact the Product
Support.
For remote disks,
check authorizations
and functionality of
non MS-Windows
servers.
5024 Cannot launch thread
″%1″ (%2) for Storage
(%3)
Internal error. Contact the Product
Support.
5025 Error executing the
script [%1] (%2) for
Storage (%3)
Error in script execution. Log on to the operating
system in the VT
Controller to check:
The Windows Event
Viewer
The log of the script
(OBSOLETE)
5026 Maximum launch of
[%1] reached for
Storage (%2)
Error in script execution. Log on to the operating
system in the VT
Controller to check:
The Windows Event
Viewer
The log of the script
5027 Error No TSM scripting
for Storage (%1)
Scripting is not
supported for TSM Data
Stores.
Remove scripting from
the configuration of
TSM Data Stores.
(OBSOLETE)