Number Text Explanation Action
5036 An invalid path [%1] is
still configured for (%2)
Windows DataStore: the
file of a virtual volume
cannot be accessed
because the path is
invalid. The Emulator
does not search in
alternate locations
because the path is still
configured.
Restore the disk path,
or
remove the path from
the pool configuration
to allow the Emulator
search in other paths
of the pool or execute
the restore script.
5037 Wrong path found [%1],
expected path [%2] for
(%3)
Windows DataStore: a
file was found in an
unexpected path.
Explain the new
location. Move the
proper file in the
expected location.
5038 Invalid path in
Configuration [%1]
A path configured in a
Windows file DataStore
is unavailable or invalid.
Restore the disk path,
or remove it from the
configuration to allow
the VTC Emulator
search in alternate
locations the files
cataloged to be in this
path.
5039 File not found on Load
for (%1)
Windows DataStore: a
file is not found.
Restore the file.
5040 Processing stops due to
volume load operation
error (%1) for (%2)
A volume load fails. A
possible reason is that a
restore script does not
complete with return-
code zero.
Refer to the log of the
script. Fix the error
condition or manually
execute the restore.
5041 WRITE operation is
denied for (%1)
A WRITE operation is
received through the
SCSI bus to a volume
loaded with “Read Only”
attribute.
This symptom can
show up if a volume is
mounted via the Stand
Alone Load Web
page, and the NonStop
application tries to
write on the virtual
volume.
Have the mount
request for regular
tape activity solved
automatically solved by
the EMS Extractor, or
by the manual load
that is available
through the Domain
Manager.