BackPak H4.00 Troubleshooting and Messages Manual
Messages
134 BackPak H4.00 Troubleshooting & Messages
Number Text Explanation Action
5097 Unexpected end of data
for VOLUME %1
Data of the named
volume is not found, or
ends unexpectedly.
Search for previous
EMS messages that
might explain why data
reading did not start,
or stopped
prematurely.
Without error in the
reading process, the
data repository is likely
to be corrupted or
truncated.
5098 Starting exporting data
from virtual volume %1
to physical volume %2
In an export operation,
data begins to be
written to the physical
media.
None
(OBSOLETE)
5099 Starting importing data
from physical %1
volume to virtual
volume %2
In an import operation,
data begins to be
written to the virtual
volume
None
(OBSOLETE)
5100 Cannot [enable|disable]
compression of physical
tape device %2. Current
setting will be used
In an export operation,
attemp to enable or
disable physical tape
device compression
faild. The export
operation will continue
using the current device
setting.
None
5101 Physical Tape Device
%1 no more match
VTC's configuration
In an export/import
operation, a pre-
configured Tape devie
cannot be found in the
VTC hardware mapping.
This can happen if the
device is power off or
had been reconfigurated
(conenected to another
HBA port, Traget id/LUN
change)
1- Investigate the
problem using the
Device Manager to
see if the device is
still visible.
2- Power on the
devidce if power
off.
3- Using the BackPak
WEB interface, go
to the VTC’s
advence
configuration
screen an delete
and re-add it in
Physical Tape
Devices Attached
list