BackPak H4.00 Troubleshooting and Messages Manual
Messages
145 BackPak H4.00 Troubleshooting & Messages
Number Text Explanation Action
10100 Error parsing the
Domain Address
Configuration file (%1)
(%2)
Internal error. Contact the Product
Support.
10101 Domain Address
Configuration list has
not been refresh due to
configuration error, old
Domain list remain
active
VTC Serviecs cannot
reload the configuration
file after Domain
address update. Will
retry.
Contact the Product
Support.if message
persist for more than
10 minutes
10102 Domain Address
Configuration list has
been succesfully
refreshed from the
updated configuration
file
The update of the
Domain TCP/IP
address(es) is being
propagated.
None.
10103 Connection from %1 has
been rejected due to the
Domain Address
Filtering security
The VT Controller
receives a control
message from an
address that is not in
the list of the Domain
TCP/IP address(es).
Verify the source
address (‘from’).
If this is a legitimate
alternate address of
the NonStop server
running the Domain
manager, add it in the
Domain address page.
(OBSOLETE)
10104 Couldn't retreive the
registry key for the
Domain Address
Configuration file
Internal error. Contact the Product
Support.
10105 IPFiltering error: %1 Internal error. Contact the Product
Support.
(OBSOLETE)
10106 Error loading the
Domain Address
Configuration file. Use
the Domain Address
Configurationt pannel of
the local BackPak
Administration interface
to manage the list
The VTC has no Domain
manager address to
forward web requests
and unsollicited
messages.
VTC intallation is
incomplete.
Enter Domain address.
Ref Installtion of a VTC