BackPak H4.00 Troubleshooting and Messages Manual

Messages
33 BackPak H4.00 Troubleshooting & Messages
Number Text Explanation Action
2506 End tag %1 does not
match start tag %2 in
%3
Invalid XML syntax.
Most often a
consequence of a
previous error.
Manual editing of XML
syntax: Fix the syntax.
BBSVCFG updated by
the Domain Manager:
Contact the Product
Support.
2507 Unexpected element
name %1 as root in %2
An XML document name
is unknown.
Contact the Product
Support.
2508 Config file %s not
available for rewrite,
errno: %Id
Guardian error when
accessing the
configuration file
BBSVCFG for update.
Check the error code,
the file definition, and
the security attributes.
2509 Can not save the current
config file in the backup
file %s, errno: %Id
Guardian error when
saving the previous
version of BBSVCFG.
Check the error code,
the file BBSVCFGO
definition, and the
security attributes.
2510 Can not re-open config
file %s for backup,
errno: %Id
Guardian error when
saving the previous
version of BBSVCFG.
Contact the Product
Support.
2511 Config file updated.
Backup in %s
The Domain
configuration file
BBSVCFG has been
updated.
None.
2512
EXPAT %s error %ld
Internal in parsing XML
syntax.
Contact the Product
Support.
2601 Maximum number of
TCP/IP out buffers
exceeded %1
Internal buffers for the
socket reply are
insufficient.
Contact the Product
Support.
2602 Out of memory to
allocate output buffer
Internal buffers for the
socket reply are
insufficient.
Contact the Product
Support.
2603 Socket error %1 on %2 TCP/IP error. Refer to the TCP/IP
Programming HP
NonStop manual.
Socket errors.