BackPak H4.00 Troubleshooting and Messages Manual

Messages
48 BackPak H4.00 Troubleshooting & Messages
Number Text Explanation Action
3102 VTC %s did not reply to
a Connect message.
A message is rejected
by a VT Controller, most
probably because IP
filtering.
Check the Domain
address page in the
Web page /Admin of
this VT Controller.
Check the MS Windows
Event Viewer.
3102 Library %s did not reply
to a Connect message.
A message is rejected
by the BBLM process of
this library.
Check for other EMS
messages related to
this BBLM process.
Restart the BBLM
process.
3103 BBCMD requires 2, but
received %ld command
parameters.
Internal error in the
EZX_START_XFER TACL
macro.
Contact the Product
Support.
3104 Invalid version of %s
VOLUME file: '%d',
expected: '%d'.
Discrepancy between
the version of the
VOLUME data file and
the running BBSV
program.
Check the
installation/upgrade
just executed.
3105 Excessive length of %s's
reply: %u. Total
expected: %u. Already
received: %u.
Internal error in TCPIP
communications with an
EZX MVS Agent.
Contact the Product
Support. if the problem
repeats.
3106 Invalid length in header
received from %s: %u.
Maximum expected
length.
Internal error in TCPIP
communications with an
EZX MVS Agent.
Contact the Product
Support. if the problem
reoccurs.
3107 MountId: %s. Volume
%s. Invalid keyword
'%s' in the mount
message of TAPE
DEFINE.
A load request is
rejected because an
unexpected content of
the TAPE DEFINE
comment.
Check the bbox-secure
syntax in the TAPE
DEFINE comment.
EZX product: be sure
to use the
EZX_START_XFER
macro to build the
TAPE DEFINE.