BackPak H4.00 Troubleshooting and Messages Manual
Messages
60 BackPak H4.00 Troubleshooting & Messages
Number Text Explanation Action
3178 VOLUME scan: another
scan is still executing.
New scan skipped
EZX-Gateway product:
The execution of a
VOLUME scan exceeded
the delay between two
scans.
Revise the parameter
VOLUME-SCAN-interval
in BBEXTCFG
3178 Disk model mismatch for
EZX volume %s Dataset
%s. MVS volume %s is
model %s, DataStore
%s is configured for
model %s
EZX-Gateway an MVS
disk was found with
3380 geometry when
3390 is expected, or
vice-versa.
Use only a single
geometry 3380 or
3390 per DataStore.
To use 3380 geometry,
enter Unit type '3380'
in the Data Store
configuration.
3179 MountId: %s. Dump
type (Audit/Online) is
missing for TMF volume
%s.
The TMF dump type is
not found (Load), or not
entered by user
(Virtualization)
Load is executed, but
the parameter
%BBOX_TMF_TYPE% is
not set in the Backup
script.
Virtualization is rejected
Load: contact Etinet
Virtualization: enter
the dump type for the
operation.
3180 Disk model mismatch for
EZX volume %s Dataset
%s. MVS volume %s is
model %s, DataStore
%s is configured for
model %s
EZX-Gateway product:
The disk model of an
MVS dataset does not
match the Data store
configuration
Revise the JCL
parameters entered to
create the dataset, the
MVS setup for dataset
creation, the EZX-
Gateway Data store
configuration
3181 MountId: %s for volume
%s. %s while querying
application process
%s.%d,%d. Mount
automation is disabled.
A tape application
process can not be
queried
Several load / unload
automations are disabled
.
Fix security
and resource
errors to allow regular
functionality.
Contact Etinet support
for other errors.
3182 MountId: %s for volume
%s. Previous error in
accessing VOLUME
prevents the recording
of the volume sequence
and any future pre-load.
Informative message Refer to the previous
error