Number Text Explanation Action
3252 More than %ld tape
devices are configured.
Devices in exceeds are
ignored.
Automatic mount is
limited to a maximum
number of tape devices.
Devices in excess are
ignored.
The initial maximum is
256 devices.
Contact the Product
Support.if a site
requires more devices.
3253 Domain license
violation. Physical media
Virtualization /
Materialization is not
licensed.
Virtualization /
Materialization must be
licensed to be used.
Contact the Product
Support.
3254 Physical device %s in
%s accessed as LEGACY
device for Virtualization
/ Materialization that is
not licensed for LEGACY
Physical tape devices
that are not explicitely
supported by a Windows
driver must be accessed
in LEGACY mode. This
requires a special
license option.
Change the tape device
for a device supported
by Microsoft Windows,
Or contact the Product
Support..
3255 DSM/TC pool %s in
catalog %s does not
exist.
A pool name is not
known by DSM/TC.
Verify the configuration
of the volume group
and the DSM/TC pool
names.
3256 DSM/TC pool %s in
catalog %s is defined
with APPEND ON, that is
incompatible with Auto-
scratch ON in the
BackPak volume group
%s %s.
Inconsistency in the
volume group
configuration.
Preferably change the
DSM/TC pool to
APPEND OFF.
Witch virtual tapes and
the BackPak space
management, APPEND
should be useless.
As second choice
remove auto-scratch in
the BackPak volume
group.
Volume groups for
Library management
do not offer Auto-
scratch.