BackPak H4.00 Troubleshooting and Messages Manual
Messages
75 BackPak H4.00 Troubleshooting & Messages
Number Text Explanation Action
3262 The bar-coded label is
missing in library for
element %s. Medium
ignored
Bar-code is not seen by
the library changer.
Verify printed bar-
codes and bar-code
reader of physical
libraries.
For virtual libraries,
Generate
3263 Maximum supported
number of slots %ld
exceeded by library %s.
Extra volumes ignored.
A library inventory
query returns more than
65535 slots.
Contact the Product
Support.
3264 New location %s for
volume %s in library
%s. Previous location
%s is overridden in
domain catalog. %s
A library inventory
query returns a location
for a volume that is
registered in another
slot in the BackPak
catalog.
This should happen only
after operations not
initiated by BackPak.
None. BackPak catalog
is updated accordingly
the library replies.
3265 Label '%s' in slot %s
was already seen in the
other slot %s of library
%s. New occurence
ignored.
Several volumes have
the same bar-coded
label.
Only the 1
st
occurrence
can be labeled and
operated by NSK tape
applications.
Remove and relabel
duplicates.
3266 SQL error %d (seq %d)
from %s in %s.%s line
%ld (syntax loc %d)
processed rows=%ld.
Technical error
accessing an SQL data
base.
Refer to the context
and complementary
BackPak EMS
messages.
3267 Domain license
violation. Catalog Sync
option is not licensed
The license key
registered in the domain
configuration does not
allow catalog replication.
Get an appropriate
license key from Eti-
Net
3268 Cannot submit a catalog
export/import when one
is already running for
data store %s. Process
%s was started on %s,
%s volumes processed.
Only one batch process
can run at a time for a
data store.
Wait for the end of
process.
Eventually abort the
process by a TACL
STOP command.