Fibre Channel ServerNet Adapter Installation and Support Guide (G06.28+, H06.03+)

Relocating an FCSA
Fibre Channel ServerNet Adapter Installation and Support Guide528254-012
4-3
Review Standard Operating Practices
Review Standard Operating Practices
See Review Standard Operating Practices on page 2-8 and Figure 2-1 on page 2-9.
Remove the Adapter
1. Disconnect the Fibre Channel cables one at a time by squeezing the plastic
retaining clip at the end of the cable and gently pulling.
2. Protect the equipment from electrostatic discharge:
a. Place an antistatic table mat on a flat horizontal work surface near the IOAM
enclosure.
b. Put on an ESD wrist strap.
c. Attach the grounding clip from the ESD wrist strap to any unpainted metal
surface on the IOAM enclosure or on the rack in which the enclosure is
installed.
3. Press down on the purple ejector latch and pull the FCSA’s handle outward to
unseat the adapter. (See Figure 3-1, Pressing Down on the Latch, on page 3-9.)
4. Grasp the FCSA by its ejector in one hand and pull the adapter out of its slot while
supporting the bottom edge of the FCSA with the other hand.
Install the FCSA in its New Slot
Follow the procedure described in Install the FCSA on page 2-11.
Verify the Installation of the FCSA
Follow the procedure Verify the Installation of the FCSA on page 2-14.
Caution. Do not attach the ESD grounding clip to doors or to any painted surface.
Note. The FCSA weighs approximately 7.25 pounds (3 kilograms).
Note. Make sure that you reinstall a filler panel in the empty adapter slot.