Gigabit Ethernet ServerNet Adapter Installation and Support Guide

Installing a GESA
Gigabit Ethernet Adapter Installation and Support Guide523628.005
2-15
Verify the Installation of the GESA
Verify the Installation of the GESA
Verify the installation of the GESA by examining the GESAs status LEDs. Figure 1-1
on page 1-4 shows the location of these LEDS for the 3865 GESA-C. Figure 1-2 on
page 1-6 shows the location of these LEDs for the 3865 GESA-F.
Make sure that the power-on LED (green light) is lit.
If the power-on LED is not lit:
°
Reseat the GESA. If the power-on LED is not lit after you reseat the GESA,
replace the GESA.
°
Check the GESA and backplane connector for damaged pins. If the GESA or
backplane connector has damaged pins, both the GESA and backplane (or
enclosure) must be replaced. For backplane replacement instructions, refer to
the NonStop S-Series Service Provider Supplement.
°
Use the OSM Service Connection or TSM Service Application to check for
alarms related to the GESA.
Note. When the adapter is inserted, the fault LED (amber) remains lit until the service
processor has completed its start-up configuration. The fault LED also lights when SLSA
detects a POST failure.