H06.03 Software Installation and Upgrade Guide

Updating SWAN Concentrator CLIP Firmware
H06.03 Software Installation and Upgrade Guide540066-002
C-7
To Stop the CLIPs
$SYSTEM ZWANTOOL 12> run wanlnck line $x25131,diag $system.css04.d8155p00
.
.
VPROC from CLIP: T7954G01^21OCT99^AAF^R002
.
.
To Stop the CLIPs
Use the SCF STOP ADAPTER command:
5> SCF STOP ADAPTER $ZZWAN.#S01, SUB ALL
To Verify That CLIPs Are Stopped
Use the SCF STATUS SERVER command:
2-> status server $zzwan.#s01.*
WAN Manager STATUS SERVER for CLIP \ELI.$ZZWAN.#S01.1
State :......... STOPPED
.
.
WAN Manager STATUS SERVER for CLIP \ELI.$ZZWAN.#S01.2
State :......... STOPPED
.
.
WAN Manager STATUS SERVER for CLIP \ELI.$ZZWAN.#S01.3
State :......... STOPPED
.
.
To Point SWAN Concentrators to the New Firmware Object Code
File
Use the SCF ALTER ADAPTER, KERNELCODE command:
-> SCF ALTER ADAPTER $ZZWAN.#conc-name,
KERNELCODE swan-kernel-micode-file-name
By default, the SWAN firmware object file (C7953P00) resides in the
$SYSTEM.CSSnn subvolume (nn is the number of the $SYSTEM.SYSnn where the
new operating system image resides):
SCF ALTER ADAPTER $ZZWAN.#S01, KERNELCODE $SYSTEM.CSS04.C7953P00
The SCF ALTER ADAPTER, KERNELCODE command changes the firmware file
location for all CLIPs associated with a SWAN concentrator.
Note. The SWAN concentrators (ADAPTER object) must be in the STOPPED state for this
command to work.