Native Inspect Manual (H06.07+)
Syntax of Native Inspect Commands
Native Inspect Manual—528122-006
4-30
enable display command
Example
To disable and then enable a breakpoint:
enable display command
Enables the evaluation and display of a previously disabled display expression.
If you do not specify a num, the command displays all the previously displayed
expressions on the automatic display list.
num
is an ordinal number that identifies an expression on the automatic display list.
Considerations
•
To specify an expression for automatic display, use the display command.
•
To display the expression numbers on the automatic display list, either use the info
command with the display option, or enter the display command with no
arguments.
(eInspect 1,329):disable 1
(eInspect 1,329):info break
Num Type Disp Enb Address What
1 breakpoint keep n 0x70002540 in pcbDataStructs_initialize
at
\SIERRA.$YOSE1.SYMBAT1.SCXXTST:352
stop only if pcb->pin == 2
print PCB
(eInspect 1,329):enable 1
(eInspect 1,329):info break
Num Type Disp Enb Address What
1 breakpoint keep y 0x70002540 in pcbDataStructs_initialize
at
\SIERRA.$YOSE1.SYMBAT1.SCXXTST:352
stop only if pcb->pin == 2
print PCB
enable display [ num ]