NonStop NS-Series Planning Guide (H06.03+)
Modular System Hardware
HP Integrity NonStop NS-Series Planning Guide—529567-004
2-8
Modular Cabinet PDU Keepout Panel
Modular Cabinet PDU Keepout Panel
PDU keepout applies only when the PDU junction boxes reside at the bottom of the
modular cabinet. PDUs overlap the outside of the rack by 2 U (3.5 inches). A PDU
keepout panel is installed in affected space when:
•
1U keepout applies when a UPS occupies the bottom position of the modular
cabinet.
•
2U keepout applies when a processor slice occupies the bottom position of the
modular cabinet.
Processor Slice
The slice enclosure, which is 5U high and weighs 112 pounds (46 kilograms), has
these physical attributes:
•
Rack mountable
•
Redundant AC power feeds
•
Front-to-rear cooling
•
Cable connections at rear (power, reintegration, LSU) with cable management
equipment on the rear of the cabinet
Each slice enclosure includes these field replaceable units (FRUs):
•
Processor board with up to four Intel Intanium microprocessors, interface ASIC,
clock generation (accessed through front of enclosure)
•
Memory board that can hold up to 32 DIMMs, each one 4 GB, for a total memory
capacity of 128 GB (accessed through front of enclosure)
•
DIMMs
•
Reintegration board for managing internal memory traffic (accessed from top of
enclosure when enclosure is pulled forward on its rails)
•
Optic adapter plug-in cards (PICs) with two ports; two adapters minimum, eight
maximum (accessed from top of enclosure when enclosure is pulled forward on its
rails)
•
Redundant cooling fans (accessed from top of enclosure when enclosure is pulled
forward on its rails)
•
Redundant 220-240 V ac power supplies and power cords (accessed from back of
of enclosure)
•
I/O interface board for parallel to serial conversion and maintenance logic (requires
removal of enclosure from rack)
•
Front panel with indicator LEDs and power buttons
Note. The term slice is equivalent to the term NonStop Blade Element (NSBE). In future
revisions of this publication, slice will be replaced with one of the following terms:
•
NonStop Blade Element
•
Blade Element
•
NSBE