NonStop NS-Series Planning Guide (H06.03+)

Modular System Hardware
HP Integrity NonStop NS-Series Planning Guide529567-004
2-27
Component Location and Identification
This illustration shows an example of connections between two Integrity NonStop NS-
series server IOAM enclosures and an ESS via the separate Fibre Channel switch:
For fault tolerance, the primary and backup paths to an ESS logical device (LDEV)
must go through different Fibre Channel switches.
Some storage area procedures such as reconfiguration can cause the affected
switches to pause. If the pause is long enough, I/O failure occurs on all paths
connected to that switch. If both the primary and the backup paths are connected to
the same switch, the LDEV goes down.
Refer to the documentation that accompanies the ESS.
Component Location and Identification
Topics discussed in this subsection are:
Topic Page
Terminology
2-28
Rack and Offset Physical Location 2-29
Slice Group-Module-Slot Numbering 2-29
LSU Group-Module-Slot Numbering 2-31
Processor Switch Group-Module-Slot Numbering 2-32
IOAM Enclosure Group-Module-Slot Numbering 2-33
Disk Drive Enclosure Group-Module-Slot Numbering 2-34
VST068.vsd
Fibre
Channel
Switch
ESS
IOA M
Enclosure
Fibre Channel
Switch
IOA M
Enclosure
FCSA
FCSA