- 1 System Hardware Overview
- 2 Installation Facility Guidelines
- 3 System Installation Specifications
- 4 Integrity NonStop NSSeries System Description
- NonStop System Primer
- NonStop Advanced Architecture
- NonStop Blade Complex
- Processor Element
- Duplex Processor
- Triplex Processor
- Processor Synchronization and Rendezvous
- Memory Reintegration
- Failure Recovery for Duplex Processor
- Failure Recovery for Triplex Processor
- ServerNet Fabric I/O
- System Architecture
- Modular Hardware
- NonStop S-Series I/O Hardware
- System Models
- Default Startup Characteristics
- Migration Considerations
- System Installation Document Packet
- 5 Modular System Hardware
- Modular Hardware Components
- Cabinets
- AC Power PDUs
- Modular Cabinet PDU Keepout Panel
- NonStop Blade Element
- Logical Synchronization Unit (LSU)
- LSU Indicator LEDs
- Processor Switch
- P-Switch Indicator LEDs
- Processor Numbering
- I/O Adapter Module (IOAM) Enclosure and I/O Adapters
- Fibre Channel Disk Module
- Tape Drive and Interface Hardware
- Maintenance Switch (Ethernet)
- Optional UPS and ERM
- System Console
- Enterprise Storage System
- Component Location and Identification
- NonStop S-Series I/O Enclosures
- Modular Hardware Components
- 6 System Configuration Guidelines
- Enclosure Locations in Cabinets
- Internal ServerNet Interconnect Cabling
- Cable Labeling
- Cable Management System
- Internal Interconnect Cables
- Dedicated Service LAN Cables
- Cable Length Restrictions
- Internal Cable Part Numbers
- NonStop Blade Elements to LSUs
- NonStop Blade Element to NonStop Blade Element
- LSUs to Processor Switches and Processor IDs
- Processor Switch ServerNet Connections
- Processor Switches to IOAM Enclosures
- FCSA to Fibre Channel Disk Modules
- FCSA to Tape Devices
- P-Switch to NonStop S-Series I/O Enclosure Cabling
- IOAM Enclosure and Disk Storage Considerations
- Fibre Channel Devices
- G4SAs to Networks
- Default Naming Conventions
- PDU Strapping Configurations
- 7 Example Configurations
- A Cables
- B Control, Configuration, and Maintenance Tools
- Support and Service Library
- System Console
- Maintenance Architecture
- Dedicated Service LAN
- IP Addresses
- Ethernet Cables
- SWAN Concentrator Restriction
- System-Up Dedicated Service LAN
- Dedicated Service LAN Links With One IOAM Enclosure
- Dedicated Service LAN Links to Two IOAM Enclosures
- Dedicated Service LAN Links With IOAM Enclosure and NonStop SSeries I/O Enclosure
- Dedicated Service LAN Links With NonStop S-Series I/O Enclosure
- Initial Configuration for a Dedicated Service LAN
- Operating Configurations for Dedicated Service LANs
- OSM
- System-Down OSM Low-Level Link
- AC Power Monitoring
- AC Power-Fail States
- C Guide to Integrity NonStop NSSeries Server Manuals
- Safety and Compliance
- Index

HP Integrity NonStop NS-Series Planning Guide—529567-005
Index-1
Index
A
AC current calculations 3-11
AC power
208 V ac delta 3-2, 6-36
250 V ac 3-phase 3-2, 6-37
250 V ac single-phase 3-3, 6-38
enclosure input specifications 3-4
feed, top or bottom 1-1
power-fail monitoring B-21
power-fail states B-23
unstrapped PDU 6-34
AC power feed 5-4
bottom of cabinet 5-4
top of cabinet 5-4
with cabinet UPS 5-5
air conditioning 2-4
air filters 2-5
B
branch circuit 3-3
C
cabinet 1-1, 5-24
cabinet dimensions, 3-6
cabinet, offset 5-3
cable connections
LSUs to p-switches 6-7
NonStop Blade Element to LSUs 6-7
cable labeling 6-4
cable length restrictions 6-6, A-3
cable management system (CMS) A-3
cable specifications 6-5
cables, power 2-3
cabling
FCSA to FCDM 6-23
FCSA to tape devices 6-15
processors 0 to 3 6-8
processors 12 to 15 6-12
processors 4 to 7 6-10
processors 8 to 11 6-11
p-switch to NonStop S-series I/O
enclosure 6-15
p-switches to IOAM enclosure 6-13
restrictions 6-13
calculation, heat 2-4, 3-10
calculation, weight 2-4, 3-9
clearances, service 3-6
cluster cable product IDs A-2
complex
processor description 4-2
processor ID 5-8, 5-15
configuration considerations
Fibre Channel devices 6-20
IOAM enclosures 6-18
minimum, typical’ maximum number of
enclosures 7-1
configuration examples 7-1
configuration, factory-installed hardware
documentation 4-23
controls, NonStop Blade Element front
panel 5-10
cooling assessment 2-4
D
daisy-chain disk configuration
recommendations 6-22
dedicated service LAN B-9
default disk drive locations 6-20
default startup characteristics 4-18
dimensions
enclosures 3-8
modular cabinet 3-6
service clearances 3-6
disk drive configuration
recommendations 6-21
display