NonStop NS-Series Planning Guide (H06.04+)

Table Of Contents
Modular System Hardware
HP Integrity NonStop NS-Series Planning Guide529567-005
5-13
Processor Switch
Two p-switches are required, one each for the X and Y ServerNet fabrics. Physical
attributes for the 3U-high p-switch are:
Rackmountable
Dual AC power feeds and power supplies
Dual fans with front to rear cooling
Main logic board
Maintenance entity (ME) logic and firmware
Maintenance PIC (slot 1) for connection to maintenance switch
Cluster PIC (slot 2) for connection to 6770 or 6780 cluster switch
Crosslink PIC (slot 3) for connection to the other p-switch
ServerNet I/O PICs (slots 4 to 9); provide 24 ServerNet 3 connections to one or
more IOAMs and to optional NonStop S-series I/O enclosures
Processor I/O PICs (slots 10 to 13); connect to LSU for ServerNet 3 I/O with the
processors
Cable management and connectivity on the rear of the cabinet
P-switch FRUs include:
ServerNet switch board
Quad MMF PIC (up to 10) for processor connection to LSUs and I/O connections
to IOAM enclosures, NonStop S-series I/O enclosures, and ServerNet cluster
switch (model 6780)
SMF PIC for connection to ServerNet cluster switch (model 6770)
Cross-link PIC for crossover connections between the two p-switches in the
system
Maintenance PIC for Ethernet connection to the maintenance switch and for
system power-on (SPON) connection to a NonStop S-series I/O enclosure
Power supplies (2)
Fans (2)
20-character by 2-line liquid crystal display (LCD) for configuration information:
°
IP address
°
Group-module-slot
°
Cabinet name and offset
°
ME firmware revision
°
Field programmable gate array (FPGA) firmware revision
Each p-switch is the ServerNet fabric (X or Y) hub for all local and remote ServerNet
connections. Functions of the p-switch include:
ServerNet interconnect between processors
ServerNet interconnect between processors and IOAM
ServerNet interconnect between processors and IOMF 2 for NonStop S-series I/O
enclosure
Interface for LAN and system maintenance for:
°
Processor control
Caution. To maintain proper cooling air flow, blank panels must be installed in all slots that do
not contain PICs.