NonStop NS-Series Planning Guide (H06.04+)
Table Of Contents
- What’s New in This Manual
- About This Manual
- 1 System Hardware Overview
- 2 Installation Facility Guidelines
- 3 System Installation Specifications
- 4 Integrity NonStop NSSeries System Description
- NonStop System Primer
- NonStop Advanced Architecture
- NonStop Blade Complex
- Processor Element
- Duplex Processor
- Triplex Processor
- Processor Synchronization and Rendezvous
- Memory Reintegration
- Failure Recovery for Duplex Processor
- Failure Recovery for Triplex Processor
- ServerNet Fabric I/O
- System Architecture
- Modular Hardware
- NonStop S-Series I/O Hardware
- System Models
- Default Startup Characteristics
- Migration Considerations
- System Installation Document Packet
- 5 Modular System Hardware
- Modular Hardware Components
- Cabinets
- AC Power PDUs
- Modular Cabinet PDU Keepout Panel
- NonStop Blade Element
- Logical Synchronization Unit (LSU)
- LSU Indicator LEDs
- Processor Switch
- P-Switch Indicator LEDs
- Processor Numbering
- I/O Adapter Module (IOAM) Enclosure and I/O Adapters
- Fibre Channel Disk Module
- Tape Drive and Interface Hardware
- Maintenance Switch (Ethernet)
- Optional UPS and ERM
- System Console
- Enterprise Storage System
- Component Location and Identification
- NonStop S-Series I/O Enclosures
- Modular Hardware Components
- 6 System Configuration Guidelines
- Enclosure Locations in Cabinets
- Internal ServerNet Interconnect Cabling
- Cable Labeling
- Cable Management System
- Internal Interconnect Cables
- Dedicated Service LAN Cables
- Cable Length Restrictions
- Internal Cable Part Numbers
- NonStop Blade Elements to LSUs
- NonStop Blade Element to NonStop Blade Element
- LSUs to Processor Switches and Processor IDs
- Processor Switch ServerNet Connections
- Processor Switches to IOAM Enclosures
- FCSA to Fibre Channel Disk Modules
- FCSA to Tape Devices
- P-Switch to NonStop S-Series I/O Enclosure Cabling
- IOAM Enclosure and Disk Storage Considerations
- Fibre Channel Devices
- G4SAs to Networks
- Default Naming Conventions
- PDU Strapping Configurations
- 7 Example Configurations
- A Cables
- B Control, Configuration, and Maintenance Tools
- Support and Service Library
- System Console
- Maintenance Architecture
- Dedicated Service LAN
- IP Addresses
- Ethernet Cables
- SWAN Concentrator Restriction
- System-Up Dedicated Service LAN
- Dedicated Service LAN Links With One IOAM Enclosure
- Dedicated Service LAN Links to Two IOAM Enclosures
- Dedicated Service LAN Links With IOAM Enclosure and NonStop SSeries I/O Enclosure
- Dedicated Service LAN Links With NonStop S-Series I/O Enclosure
- Initial Configuration for a Dedicated Service LAN
- Operating Configurations for Dedicated Service LANs
- OSM
- System-Down OSM Low-Level Link
- AC Power Monitoring
- AC Power-Fail States
- C Guide to Integrity NonStop NSSeries Server Manuals
- Safety and Compliance
- Index

Modular System Hardware
HP Integrity NonStop NS-Series Planning Guide—529567-005
5-30
Fibre Channel Disk Module Group-Module-Slot
Numbering
Fibre Channel Disk Module Group-Module-Slot Numbering
The form of the GMS numbering for a disk in a Fibre Channel disk module is:
This example shows the disk in slot 03 of the Fibre Channel disk module that connects
to the FCSA in the IOAM group 111, module 2, slot 1,FSAC 1:
IOAM
Group
IOAM
Module
IOAM
Slot
FCSA
F-SACs
Fibre Channel
Disk Module
Shelf
FCDM
Slot Item
110-115 2 - X
fabric;
3 - Y
fabric
1 - 5 1, 2 1 - 4 if daisy-
chained;
1 if single disk
enclosure
0 Fibre Channel disk
module
1-14 Disk drives
89 Transceiver A1
90 Transceiver A2
91 Transceiver B1
92 Transceiver B2
93 Left FC-AL board
94 Right FC-AL board
95 Left power supply
96 Right power supply
97 Left blower
98 Right blower
99 EMU
VST505.vsd
111.211.103
IOAM group number housing FCSA
FCDM number
IOAM module housing FCSA
IOAM slot housing FCSA
ServerNet addressable controller (SAC) number in FCSA
FCDM slot housing FRU
GMS Number for disk drive
VST502.vsd
Slot 5
Slot 4
Slot 3
Slot 2
Slot 1
Slot 5
Slot 4
Slot 3
Slot 2
IOAM
(Module 2)
IOAM
(Module 3)
FCSA
(Slot 1)
FSAC
1
FSAC
2
Fibre Channel
Disk Module 1
(front)
1-14
Disk
Slot 3
94
97
93
95
Fibre Channel
Disk Module 1
(back)
99
96
98
89
90
91
92