NonStop NS-Series Planning Guide (H06.05+)
Cables
HP Integrity NonStop NS-Series Planning Guide—529567-008
A-3
Cable Length Restrictions
Cable Length Restrictions
Maximum allowable lengths of cables connecting the modular system components are:
Although a considerable distance can exist between the modular enclosures in the
system, HP recommends placing all cabinets adjacent to each other and bolting them
together, with cable length between each of the enclosures as short as possible.
Cable Management System
The cable management system (CMS) for Integrity NonStop NS-series systems
contains cable trays and vertical cable guides and is designed specifically for the
Integrity NonStop NS-series server components to manage all fiber cables, CAT5
cables, and for some components and power cords. Using the CMS maintains the
minimum 25mm bend radius for the fiber cables and provides strain relief for the fiber-
optic cables and the power cords. For details on using the CMS, refer to the NonStop
NS-Series Hardware Installation Manual.
Connection
Fiber
Type Connectors
Maximum
Length Product ID
NonStop Blade Element to LSU
enclosure
MMF LC-LC 100 m M8900nnn
1
NonStop Blade Element to NonStop
Blade Element
MMF MTP 50 m M8920nnn
1
LSU enclosure to p-switch MMF LC-LC 125 m M8900nnn
1
P-switch to p-switch crosslink MMF LC-LC 125 m M8900nnn
1
P-switch to IOAM enclosure MMF LC-LC 125 m M8900nnn
1
FCSA to Fibre Channel disk module MMF LC-LC 250 m M8900nnn
1
FCSA to ESS MMF LC-LC 250 m M8900nnn
1
FCSA to FC switch MMF LC-LC 250 m M8900nnn
1
P-switch to cluster switch 6780 MMF LC-LC 100 m M8900nnn
1
P-switch to cluster switch 6770 SMF LC-SC 80 m M8922nnn
1
P-switch to NonStop S-series IOMF 2 MMF LC-SC 100 m M8910nnn
1
1
nnn indicates the length of the cable in meters. For example, M8900125 is 125 meters