NonStop NS1000 Planning Guide (H06.05+)

Modular System Hardware
HP Integrity NonStop NS1000 Planning Guide542527-004
5-14
Blade Element Group-Module-Slot Numbering
The form of GMS numbering for a blade element displayed in the OSM Service
Connection is:
OSM Service Connection GMS Numbering:
Processor ID
Group*
Module
Slot
Port
(Slot 2 only)Blade Element Processor
0 400 1 100 2,
PCI
adapter
3-4,
Power
supplies
17-19,
Fans
X
Y
1 401 1 101
2 402 1 102
3 403 1 103
4 404 1 104
5 405 1 105
6 406 1 106
7 407 1 107
OSM Low-Level GMS Numbering:
Processor ID Group* Module Slot
0 400 100 1
1 400 101 1
2 400 102 1
3 400 103 1
4 400 104 1
5 400 105 1
6 400 106 1
7 400 107 1
*In OSM, the term Blade Complex is used for the group.
401.1.3
Blade element slot (for example, a power supply)
Blade element module
Blade group number comprising blade element
components
VST013.vsd
401.101
Processor (for example, processor 1)
Blade element module
Blade group number comprising blade element
components