NonStop NS1000 Planning Guide (H06.05+)

Modular System Hardware
HP Integrity NonStop NS1000 Planning Guide542527-004
5-16
Fibre Channel Disk Module (FCDM) Group-Module-
Slot Numbering
This illustration shows the slot locations for the IOAM enclosure:
Fibre Channel Disk Module (FCDM) Group-Module-Slot
Numbering
IOAM
Group
IOAM
Module
IOAM
Slot
FCSA
Controller
Port FCDM Shelf
FCDM
Slot Item
100 2: X
fabric;
3: Y
fabric
3 - 5 1, 2 1 - 4 if daisy-
chained;
1 if single disk
module
0 FCDM
1-14 Disk drive bays
89 Transceiver A1
90 Transceiver A2
91 Transceiver B1
92 Transceiver B2
93 Left FC-AL board
94 Right FC-AL board
95 Left power supply
96 Right power supply
97 Right blower
98 Left blower
99 EMU
IOAM Enclosure Rear
(Group 100)
IOAM Enclosure Front
(Group 100)
Power Supplies
(Modules 2 and 3)
Fans
(Mod 3
Slot 17)
Fans
(Mod 2
Slot 17)
Fans
(Mod 3
Slot 16)
Fans
(Mod 2
Slot 16)
Slot 1
Slot 5
Slot 4
Slot 3
Slot 2
Slot 1
Slot 5
Slot 4
Slot 3
Slot 2
IOAM
(Module 2)
IOAM
(Module 3)
Slot
15
Slot
18
Slot
15
Slot
18
Power Supplies
ServerNet Switch Board
(Module 3, Slot 14)
VST003.vsd
4PSEs
Slots 1 and 2
ServerNet Adapters
Slots 3-5
Module 2
Module 3
Module 2
Module 3
ServerNet Switch Board
(Module 2, Slot 14)
Maintenance Connector
(100 BaseT RJ-45)
LCD
Display