IP Addresses
Integrity NonStop NS1000 servers require Internet protocol (IP) addresses for these
components that are connected to the dedicated service LAN:
ServerNet switch boards in the IOAM enclosure
Maintenance switches
System consoles
G4SAs
UPSs (optional)
These components have default IP addresses that are preconfigured at the factory.
You must change these preconfigured IP addresses to addresses appropriate for the
LAN environment:
Component Location GMS
Default IP
Address Used By
IOAM enclosure N/A 100.2.14
100.3.14
192.231.36.222
192.231.36.223
OSM Low Level
Link
Maintenance switch
(ProCurve 2524)
Additional switches
(rackmounted only)
Rack 01
Rack 02
N/A
N/A
192.231.36.21
192.231.36.22
192.231.36.23,
192.231.36.24,
...
192.231.36.n
OSM Service
Connection
Primary system console
(rackmounted or stand-
alone)
Backup system console
(rackmounted only)
Up to two additional system
consoles (rackmounted
only)
N/A
N/A
N/A
N/A
N/A
N/A
192.231.36.1
192.231.36.4
192.231.36.5
192.231.36.6
OSM Low Level
Link
OSM Service
Connection
OSM
Notification
Director
UPS (rackmounted only)
UPS (not rackmounted)
Rack 01
Rack 02
Rack 03
N/A
N/A
N/A
192.231.36.31
192.231.36.32
192.231.36.33
192.72.173.188
OSM Service
Connection
TCP/IP processes for OSM:
$ZTCP0
$ZTCP1
First G4SA (port A)
Second G4SA (port A)
192.231.36.10
192.231.36.11
OSM Service
Connection
OSM
Notification
Director