NonStop NS1000 Planning Guide (H06.06+)
Control, Configuration, and Maintenance Tools
HP Integrity NonStop NS1000 Planning Guide—542527-002
B-13
System-Up Dedicated Service LAN
System-Up Dedicated Service LAN
When the system is up and the OS running, the ME connects to the NonStop NS1000
system’s dedicated service LAN using one of the PIFs on each of two G4SAs. This
connection enables OSM Service Connection and OSM Notification Director
communication for maintenance in a running system.
For a fault-tolerant dedicated service LAN, two G4SAs are required, with one
connected to each ServerNet fabric, X and Y. These G4SAs can reside in modules 2
and 3 of the same IOAM enclosure. When the G4SA provides connection to the
dedicated service LAN, use the slower 10/100 Mbps PIF A rather than one of the high-
speed 1000 Mbps Ethernet ports of PIF C or D.
VST340.vsd
Module 2
Module 3
Maintenance Switch
IOAM
Enclosure
(Group
110)
G4SA Ethernet
PIF Connectors
Cable to
Maintenance
Switch
B
A
C
D