NonStop NS1000 Planning Guide (H06.06+)
Modular System Hardware
HP Integrity NonStop NS1000 Planning Guide—542527-002
5-13
I/O Adapter Module (IOAM) Enclosure and I/O
Adapters
For information about installing the Integrity NonStop NS1000 server hardware, refer to
the NonStop NS1000 Hardware Installation Manual.
For additional information about the HP Integrity rx2620 server, refer to the HP
Cybrary: rx2620 home page:
http://cybrary.inet.cpqcorp.net/HW/SYS/INTEL/SERVER/SERVER_RX262
0/index.html
I/O Adapter Module (IOAM) Enclosure and I/O Adapters
The IOAM enclosure provides the Integrity NonStop NS1000 server with its system I/O.
For a general description of the IOAM enclosure and I/O adapters, refer to the
NonStop NS-Series Planning Guide. Details about the use or implementation of the
IOAM enclosure and I/O adapters that are specific to an Integrity NonStop NS1000
server are presented here:
•
Only one IOAM enclosure is supported in an Integrity NonStop NS1000 server.
•
The group number for the IOAM enclosure is 100 in an Integrity NonStop NS1000
system.
•
The maintenance entity on the ServerNet switch board supports direct connections
to blade elements and ServerNet I/O adapters.
•
Up to four 4PSEs provide ServerNet connectivity to the blade elements.
•
Only 4PSEs are supported for installation in slots 2.1, 2.2, 3.1, and 3.2 of the IOAM
enclosure for an Integrity NonStop NS1000 server.
•
Up to six ServerNet I/O adapters are supported, and a minimum of two FCSAs and
two G4SAs must be installed. Fibre Channel ServerNet adapters (FCSAs) are
used for communicating with storage devices such as a Fibre Channel Disk
Module, tape devices, or an Enterprise Storage System (ESS) disk. Gigabit
Ethernet 4-port ServerNet adapters (G4SAs) are used for Ethernet connectivity.
•
FCSAs and G4SAs are supported for installation in slots 2.3, 2.4, 2.5, 3.3, 3.4, and
3.5 of the IOAM enclosure for an Integrity NonStop NS1000 server.
•
In OSM, IOAM power supplies have actions to configure the power source as AC
or UPS in case of power failure.
Fibre Channel Disk Module
The Fibre Channel disk module (FCDM) is a storage device containing disk drives that
connect to an FCSA in an IOAM enclosure in an Integrity NonStop NS1000 server. For
a general description of the Fibre Channel disk module, refer to the NonStop NS-
Series Planning Guide. Details about the use or implementation of the Fibre Channel
disk module that are specific to an Integrity NonStop NS1000 server are presented
here.