NonStop NS1000 Planning Guide (H06.07+)

Modular System Hardware
HP Integrity NonStop NS1000 Planning Guide542527-003
5-21
Blade Element Group-Module-Slot Numbering
These tables show the default numbering for the blade elements of an Integrity
NonStop NS1000 system when blade elements are powered on and functioning:
Note. In OSM, if a blade element is not present or is powered off, processors might be
renumbered. For example, if processor 3 has been removed, processor 4 becomes processor
3 in OSM displays.
GMS Numbering Displayed in the OSM Service Connection:
Processor
ID
Group*
Module
Slot
Port
(Slot 2 only)Blade Element Processor
0 400 1 100 2, PCI adapter
3-4, power supplies
16-17, system fan
18, memory fan
19, PCI fan
X
Y
1 401 1 101
2 402 1 102
3 403 1 103
4 404 1 104
5 405 1 105
6 406 1 106
7 407 1 107
*In OSM, the term Blade Complex is used for the group.
GMS Numbering Displayed in the OSM Low-Level Link:
Processor ID Group* Module Slot
0 400 100 1
1 400 101 1
2 400 102 1
3 400 103 1
4 400 104 1
5 400 105 1
6 400 106 1
7 400 107 1