NonStop NS1000 Planning Guide (H06.07+)

Modular System Hardware
HP Integrity NonStop NS1000 Planning Guide542527-003
5-25
Fibre Channel Disk Module (FCDM) Group-Module-
Slot Numbering
Fibre Channel Disk Module (FCDM) Group-Module-Slot
Numbering
The form of GMS numbering for a disk in a Fibre Channel disk module is:
This example shows the disk in bay 03 of the Fibre Channel disk module that connects
to the FCSA in the IOAM group 100, module 2, slot 3,FSAC 1:
IOAM
Group
IOAM
Module
IOAM
Slot
FCSA
Controller
Port FCDM Shelf
FCDM
Slot Item
100 2: X
fabric;
3: Y
fabric
3 - 5 1, 2 1 - 4 if daisy-
chained;
1 if single disk
module
0 FCDM
1-14 Disk drive bays
89 Transceiver A1
90 Transceiver A2
91 Transceiver B1
92 Transceiver B2
93 Left FC-AL board
94 Right FC-AL board
95 Left power supply
96 Right power supply
97 Right blower
98 Left blower
99 EMU
VST505.vsd
100.231.103
IOAM group number housing FCSA
FCDM shelf number
IOAM module housing FCSA
IOAM slot housing FCSA
ServerNet addressable controller (SAC) number in FCSA
FCDM bay housing disk
GMS number for disk drive
VST502.vsd
Slot 5
Slot 4
Slot 2
Slot 1
Slot 5
Slot 4
Slot 3
Slot 2
IOAM
(Module 2)
IOAM
(Module 3)
FSAC
1
FSAC
2
Fibre Channel
Disk Module 1
(front)
1-14
Disk
Bay 3
94
97
93
95
Fibre Channel
Disk Module 1
(back)
99
96
98
89
90
91
92
Slot 1
FCSA
(Slot 3)