NonStop NS1000 Planning Guide (H06.08+)
Cable Length Restrictions
Maximum allowable lengths of cables connecting the modular system components are:
Product IDMaximum LengthConnectorsFiber TypeConnection
M8900nnn
1
125 mLC-LCMMFBlade element to VIO
enclosure
(ServerNet-to-processor
port)
M8900nnn
1
50mLC-LCMMFVIO enclosure to VIO
enclosure (cross-link
connection)
M8900nnn
1
250 mLC-LCMMFVIO enclosure (Fibre
Channel port) to Fibre
Channel disk module
M8900nnn
1
250 mLC-LCMMFVIO enclosure (Fibre
Channel port) to ESS
M8900nnn
1
250 mLC-LCMMFVIO enclosure (Fibre
Channel port) to FC
switch
1
nnn indicates the length of the cable in meters. For example, M8900125 is 125 meters long; M8900-15 is 15 meters
long.
Although a considerable distance can exist between the modular enclosures in the system, HP
recommends placing all cabinets adjacent to each other and bolting them together, with cable
length between each of the enclosures as short as possible.
108 Cables