NonStop NS1000 Planning Guide (H06.08+)

IP Addresses
Integrity NonStop NS1000 servers require Internet protocol (IP) addresses for these components
that are connected to the dedicated service LAN:
VIO enclosure logic boards
Maintenance switches
System consoles
UPSs (optional)
Blade iLOs
NOTE: As of the H06.05 RVU, Blade iLO IP addresses are configured using DHCP. If you
require static Blade iLO IP addresses, use the IP addresses listed below for this component.
These components have default IP addresses that are preconfigured at the factory. You must
change these preconfigured IP addresses to addresses appropriate for the LAN environment:
Used ByDefault IP AddressGroup.Module.SlotComponent
OSM Low-Level Link192.231.36.202100.2VIO enclosure
192.231.36.203100.3
OSM Service Connection192.231.36.21N/AMaintenance switch
(ProCurve) (rackmounted)
192.231.36.22N/A
192.231.36.23,
192.231.36.24,
... 192.231.36.n
N/AAdditional switches
(rackmounted only)
OSM Low-Level Link
OSM Service Connection
OSM Notification Director
192.231.36.1N/APrimary system console
(rackmounted or
stand-alone)
192.231.36.4N/ABackup system console
(rackmounted only)
192.231.36.5
192.231.36.6
N/AUp to two additional system
consoles (rackmounted
only)
OSM Service Connection192.231.36.31N/AUPS (rackmounted only)
192.231.36.32
192.231.36.33N/AUPS (non-rackmounted)
192.72.173.188
Integrated Lights-Out
Management Processor (iLO
MP)
For more information, see
the HP Integrity iLO 2 MP
Operations Guide.
192.231.36.40
192.231.36.41
192.231.36.42
192.231.36.43
192.231.36.44
192.231.36.45
192.231.36.46
192.231.36.47
N/ABlade iLO
TCP/IP processes for OSM:
OSM Service Connection192.231.36.10100.2.6b port A$ZTCP0
OSM Notification Director192.231.36.11100.3.6b port A$ZTCP1
Dedicated Service LAN 115