NonStop NS1000 Planning Guide (H06.08+)

NOTE: Although it is not a requirement for fault tolerance to house the primary and mirror
disk drives in separate FCDMs, the example configurations show FCDMs housing only primary
or mirror drives, mainly for simplicity in keeping track of the physical locations of the drives.
Four Fibre Channel Ports, Two FCDMs, Two VIO Enclosures
This illustration shows example cable connections between four Fibre Channel ports (two on
each VIO enclosure) and the primary and mirror FCDMs:
This table lists the Fibre Channel port group-module-slot-port (GMSP) and disk
group-module-shelf-bay (GMSB) identification for the factory-default system disk locations in
the configuration of four Fibre Channel ports, two FCDMs, and two VIO enclosures:
Disk GMSB
1
Fibre Channel Port GMSPDisk Volume Name
100.211.101100.2.1.1 and 100.3.1.1$SYSTEM (primary)
100.211.102100.2.1.1 and 100.3.1.1$DSMSCM (primary)
100.211.103100.2.1.1 and 100.3.1.1$AUDIT (primary)
100.211.104100.2.1.1 and 100.3.1.1$OSS (primary)
100.212.101100.2.1.2 and 100.3.1.2$SYSTEM (mirror)
100.212.102100.2.1.2 and 100.3.1.2$DSMSCM (mirror)
100.212.103100.2.1.2 and 100.3.1.2$AUDIT (mirror)
100.212.104100.2.1.2 and 100.3.1.2$OSS (mirror)
1 For an illustration of the factory-default slot locations for an FCDM, see “Factory-Default Locations for Disk Volumes”
(page 84).
86 System Configuration Guidelines