Cables and switches vary, depending on whether the connection is direct, switched, or a
combination:
Fibre Channel SwitchesLC-LC CablesConnection
02 Fibre Channel portsDirect connect
1 or more4 Fibre Channel portsSwitched
12 Fibre Channel ports for each direct
connection4 Fibre Channel ports for
each switched connection
Combination of direct and switched
This illustration shows an example of connections between two VIO enclosures and an ESS via
separate Fibre Channel switches:
For fault tolerance, the primary and backup paths to an ESS logical device (LDEV) must go
through different Fibre Channel switches.
Some storage area procedures, such as reconfiguration, can cause the affected switches to pause.
If the pause is long enough, I/O failure occurs on all paths connected to that switch. If both the
primary and the backup paths are connected to the same switch, the LDEV goes down.
Refer to the documentation that accompanies the ESS.